{"id":29030,"date":"2023-12-21T08:13:11","date_gmt":"2023-12-21T08:13:11","guid":{"rendered":"https:\/\/kb.sambapos.com\/?p=29030"},"modified":"2026-02-02T13:16:53","modified_gmt":"2026-02-02T13:16:53","slug":"8-16-datalogic-magellan-scale-configuration","status":"publish","type":"post","link":"https:\/\/kb.sambapos.com\/en\/8-16-datalogic-magellan-scale-configuration\/","title":{"rendered":"8.16. Datalogic Magellan (93-9400) Scale Configuration"},"content":{"rendered":"\r\n<p>In this document, it will be explained how to configure Datalogic Magellan Scale on SambaPOS.<\/p>\r\n<p>&nbsp;<\/p>\r\n<h3>How It Works;<\/h3>\r\n<p><strong><a href=\"https:\/\/www.youtube.com\/watch?v=Oqiux8mtXjI\" target=\"_blank\" rel=\"noopener\">https:\/\/www.youtube.com\/watch?v=Oqiux8mtXjI<\/a><\/strong><\/p>\r\n<p>&nbsp;<\/p>\r\n<p>&nbsp;<\/p>\r\n<h2><span style=\"color: #ff0000;\">Important Note:<\/span><\/h2>\r\n<p><span style=\"color: #ff0000;\"><strong>In order to use Datalogic Magellan Scale Integration you need to have minimum SambaPOS 5.7.12 version.<\/strong><\/span><\/p>\r\n<p>&nbsp;<\/p>\r\n<h3><strong>1.<\/strong><strong>\u00a0Installing Scale Module on Samba Market<\/strong><\/h3>\r\n<p>You need to install\u00a0<strong>Scale Module<\/strong>\u00a0on Samba Market and<strong>\u00a0<span style=\"color: #ff0000;\">restart the SambaPOS.<\/span><\/strong><\/p>\r\n<p>Main Menu &gt; Samba Market &gt; Click on\u00a0<strong>Install<\/strong>\u00a0button in Scale Module Part.<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-29880 size-large\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-03-1024x549.jpg\" alt=\"\" width=\"640\" height=\"343\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-03-1024x549.jpg 1024w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-03-300x161.jpg 300w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-03-768x412.jpg 768w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-03-1536x823.jpg 1536w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-03.jpg 1920w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><\/p>\r\n<p>&nbsp;<\/p>\r\n<p>&nbsp;<\/p>\r\n<h3><strong>2. Adding Datalogic Scale as Device on SambaPOS<\/strong><\/h3>\r\n<p>Go to<strong> Main Menu &gt; Manage &gt; Settings &gt; Local Settings &gt; Devices &gt; Add Device &gt; Select Datalogic Scale <\/strong>and click on <strong>Save.<\/strong><\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-29878 size-large\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-01-1024x548.jpg\" alt=\"\" width=\"640\" height=\"343\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-01-1024x548.jpg 1024w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-01-300x160.jpg 300w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-01-768x411.jpg 768w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-01-1536x822.jpg 1536w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-01.jpg 1920w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><\/p>\r\n<p>After completing necessary editings, click on <strong>Save<\/strong> button.<\/p>\r\n<p>&nbsp;<\/p>\r\n<p>&nbsp;<\/p>\r\n<h3><strong>3. Adding Automation Command-Action-Rule to Start Scale<\/strong><\/h3>\r\n<p><span style=\"color: #ff0000;\"><strong>You need to click on Start Reading Scale button to start the weighing process.<\/strong><\/span><\/p>\r\n<p>&nbsp;<\/p>\r\n<p><strong>3.1. Adding Automation Command<\/strong><\/p>\r\n<p><strong>General Settings Section;<\/strong><\/p>\r\n<p><strong>Main Menu &gt; Manage &gt; Automation &gt; Automation Commands &gt;<\/strong> Here click on <strong>Add Automation Command<\/strong><\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-29876 size-large\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-02-1024x549.jpg\" alt=\"\" width=\"640\" height=\"343\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-02-1024x549.jpg 1024w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-02-300x161.jpg 300w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-02-768x412.jpg 768w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-02-1536x824.jpg 1536w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-02.jpg 1920w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><\/p>\r\n<p><strong>Name:<\/strong> Start Reading Scale<\/p>\r\n<p><strong>Button Header:<\/strong> Start\\rReading Scale<\/p>\r\n<p>&nbsp;<\/p>\r\n<p><strong>Mappings Section;<\/strong><\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-29882 size-large\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-04-1024x549.jpg\" alt=\"\" width=\"640\" height=\"343\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-04-1024x549.jpg 1024w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-04-300x161.jpg 300w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-04-768x412.jpg 768w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-04-1536x824.jpg 1536w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-04.jpg 1920w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><\/p>\r\n<p>In here add a line by clicking on <strong>Add<\/strong> button.<\/p>\r\n<p>After completing necessary editings, click on <strong>Save<\/strong> button.<\/p>\r\n<p>&nbsp;<\/p>\r\n<p>&nbsp;<\/p>\r\n<p><strong>3.2. Adding Action<\/strong><\/p>\r\n<p><strong>Main Menu &gt; Manage &gt; Automation &gt; Actions&gt;<\/strong> Here, click on <strong>Add Action<\/strong><\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-29884 size-large\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-05-1024x549.jpg\" alt=\"\" width=\"640\" height=\"343\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-05-1024x549.jpg 1024w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-05-300x161.jpg 300w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-05-768x412.jpg 768w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-05-1536x824.jpg 1536w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-05.jpg 1920w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><\/p>\r\n<p><strong>Action Name:<\/strong> Start Reading Scale<\/p>\r\n<p><strong>Action Type:<\/strong> Datalogic Scale Operation<\/p>\r\n<p><strong>Parameters:<\/strong> True<\/p>\r\n<p>After completing necessary editings, click on <strong>Save<\/strong> button.<\/p>\r\n<p>&nbsp;<\/p>\r\n<p>&nbsp;<\/p>\r\n<p><strong>3.3. Adding Rule<\/strong><\/p>\r\n<p><strong>Main Menu &gt; Manage &gt; Automation &gt; Rules&gt;<\/strong> Here, click on <strong>Add Rule<\/strong><\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-29886 size-large\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-06-1024x549.jpg\" alt=\"\" width=\"640\" height=\"343\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-06-1024x549.jpg 1024w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-06-300x161.jpg 300w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-06-768x412.jpg 768w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-06-1536x824.jpg 1536w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-06.jpg 1920w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><\/p>\r\n<p><strong>Rule Name: <\/strong>Start Reading Scale<\/p>\r\n<p><strong>Event Name:\u00a0<\/strong>Automation Command Executed<\/p>\r\n<p><strong>Execute rule if:\u00a0<\/strong>Matches<\/p>\r\n<p><strong>Add Custom Constraint:<\/strong><\/p>\r\n<p>Automation Command Name|Equals|Start Reading Scale<\/p>\r\n<p><strong>Select Actions:<\/strong><\/p>\r\n<p><strong>Action:<\/strong> Start Reading Scale<\/p>\r\n<p>After completing necessary editings, click on <strong>Save<\/strong> button.<\/p>\r\n<p>&nbsp;<\/p>\r\n<p>&nbsp;<\/p>\r\n<p>&nbsp;<\/p>\r\n<h3><strong>4. Setting Up Datalogic Scale<\/strong><\/h3>\r\n<h4><strong>4.1. Installing Datalogic Scale Driver<\/strong><\/h4>\r\n<p>You can find all the necessary file in<strong><span style=\"color: #ff0000;\">\u00a0<a style=\"color: #ff0000;\" href=\"http:\/\/update.sambapos.com\/Datalogic-Magellan-Scale-Settings.zip\">here.<\/a><\/span><\/strong><\/p>\r\n<p>Extract the Opos folder and open the 610005425 folder and then right click on setup file and select Run as Administrator<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-29045 size-large\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-03-1-1024x803.jpg\" alt=\"\" width=\"640\" height=\"502\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-03-1-1024x803.jpg 1024w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-03-1-300x235.jpg 300w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-03-1-768x602.jpg 768w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-03-1.jpg 1153w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><\/p>\r\n<p>&nbsp;<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-29047 size-full\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-04.jpg\" alt=\"\" width=\"623\" height=\"511\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-04.jpg 623w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-04-300x246.jpg 300w\" sizes=\"auto, (max-width: 623px) 100vw, 623px\" \/><\/p>\r\n<p>&nbsp;<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-29051 size-full\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-05.jpg\" alt=\"\" width=\"623\" height=\"511\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-05.jpg 623w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-05-300x246.jpg 300w\" sizes=\"auto, (max-width: 623px) 100vw, 623px\" \/><\/p>\r\n<p>&nbsp;<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-29053 size-full\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-06.jpg\" alt=\"\" width=\"623\" height=\"511\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-06.jpg 623w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-06-300x246.jpg 300w\" sizes=\"auto, (max-width: 623px) 100vw, 623px\" \/><\/p>\r\n<p>&nbsp;<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-29055 size-full\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-07.jpg\" alt=\"\" width=\"623\" height=\"511\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-07.jpg 623w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-07-300x246.jpg 300w\" sizes=\"auto, (max-width: 623px) 100vw, 623px\" \/><\/p>\r\n<p>&nbsp;<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-29058 size-full\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-08.jpg\" alt=\"\" width=\"623\" height=\"511\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-08.jpg 623w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-08-300x246.jpg 300w\" sizes=\"auto, (max-width: 623px) 100vw, 623px\" \/><\/p>\r\n<p>&nbsp;<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-29060 size-full\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-09.jpg\" alt=\"\" width=\"623\" height=\"511\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-09.jpg 623w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-09-300x246.jpg 300w\" sizes=\"auto, (max-width: 623px) 100vw, 623px\" \/><\/p>\r\n<p>&nbsp;<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-29062 size-full\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-10.jpg\" alt=\"\" width=\"552\" height=\"201\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-10.jpg 552w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-10-300x109.jpg 300w\" sizes=\"auto, (max-width: 552px) 100vw, 552px\" \/><\/p>\r\n<p>&nbsp;<\/p>\r\n<p>&nbsp;<\/p>\r\n<h4><strong>4.2. Setting Up OPOS Properties Editor<\/strong><\/h4>\r\n<p>You can find the OPOS Properties Editor file from below path;<\/p>\r\n<p>C:\\Program Files (x86)\\DLSOPOS\\OPE<\/p>\r\n<p>&nbsp;<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-29064 size-large\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-11-1024x975.jpg\" alt=\"\" width=\"640\" height=\"609\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-11-1024x975.jpg 1024w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-11-300x286.jpg 300w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-11-768x731.jpg 768w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-11.jpg 1134w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><\/p>\r\n<h4>\u00a0<\/h4>\r\n<h4>\u00a0<\/h4>\r\n<h4><strong>4.2.0. COM Ports<\/strong><\/h4>\r\n<p>If you know the COM port connection features of the devices, you can proceed to the below step and enter these features for the scanner and the scale.<br \/>If you don&#8217;t know, the safest thing is setting device COM Ports as )600 8 N 1 mode by using the Barcode and QR Codes which are found in the booklet.<br \/>To do this, read the barcodes and QR codes below in numerical order.<br \/>These barcodes permanently change your device&#8217;s Com port reading settings.<\/p>\r\n<p><strong>Enter Barcode;<\/strong><\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-29297 size-full\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-QR-00-1.jpg\" alt=\"\" width=\"764\" height=\"936\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-QR-00-1.jpg 764w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-QR-00-1-245x300.jpg 245w\" sizes=\"auto, (max-width: 764px) 100vw, 764px\" \/><\/p>\r\n<p>&nbsp;<\/p>\r\n<p><strong>9600 QR Code;<\/strong><\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-29295 size-full\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-QR-01.jpg\" alt=\"\" width=\"765\" height=\"936\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-QR-01.jpg 765w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-QR-01-245x300.jpg 245w\" sizes=\"auto, (max-width: 765px) 100vw, 765px\" \/><\/p>\r\n<p>&nbsp;<\/p>\r\n<p><strong>Exit Barcode;<\/strong><\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-29301 size-full\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-QR-00-2.jpg\" alt=\"\" width=\"764\" height=\"936\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-QR-00-2.jpg 764w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-QR-00-2-245x300.jpg 245w\" sizes=\"auto, (max-width: 764px) 100vw, 764px\" \/><\/p>\r\n<p>&nbsp;<\/p>\r\n<p>&nbsp;<\/p>\r\n<p><strong>Enter Barcode;<\/strong><\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-29303 size-full\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-QR-00-3.jpg\" alt=\"\" width=\"764\" height=\"936\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-QR-00-3.jpg 764w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-QR-00-3-245x300.jpg 245w\" sizes=\"auto, (max-width: 764px) 100vw, 764px\" \/><\/p>\r\n<p>&nbsp;<\/p>\r\n<p>&nbsp;<\/p>\r\n<p><strong>Scale Interface Settings;<\/strong><\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-29299 size-full\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-QR-02.jpg\" alt=\"\" width=\"760\" height=\"936\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-QR-02.jpg 760w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-QR-02-244x300.jpg 244w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><\/p>\r\n<p>&nbsp;<\/p>\r\n<p><strong>Exit Barcode;<\/strong><\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-29305 size-full\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-QR-00-4.jpg\" alt=\"\" width=\"764\" height=\"936\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-QR-00-4.jpg 764w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/Datalogic-QR-00-4-245x300.jpg 245w\" sizes=\"auto, (max-width: 764px) 100vw, 764px\" \/><\/p>\r\n<p>&nbsp;<\/p>\r\n<p>You can check<span style=\"color: #ff0000;\"><strong> <a style=\"color: #ff0000;\" href=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/12\/MGL9300-9400-PRG_compressed.pdf\">this user manuel<\/a> <\/strong><\/span>as reference.<\/p>\r\n<p>&nbsp;<\/p>\r\n<p>&nbsp;<\/p>\r\n<h4><strong>4.2.1. Service Section<\/strong><\/h4>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-29066 size-full\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-12.jpg\" alt=\"\" width=\"795\" height=\"716\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-12.jpg 795w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-12-300x270.jpg 300w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-12-768x692.jpg 768w\" sizes=\"auto, (max-width: 795px) 100vw, 795px\" \/><\/p>\r\n<p>&nbsp;<\/p>\r\n<h4><strong>4.2.2. Scanners Section<\/strong><\/h4>\r\n<p><strong>MagellanSC Part;<\/strong><\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-29070 size-full\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-13.jpg\" alt=\"\" width=\"795\" height=\"716\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-13.jpg 795w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-13-300x270.jpg 300w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-13-768x692.jpg 768w\" sizes=\"auto, (max-width: 795px) 100vw, 795px\" \/><\/p>\r\n<p><strong>COM Port:<\/strong> You need to select your COM Ports accordingly<\/p>\r\n<p><strong>Baud Rate:<\/strong> Must be 9600<\/p>\r\n<p><strong>Data Bits:<\/strong> Must be 8<\/p>\r\n<p><strong>Stop Bits:<\/strong> Must be One<\/p>\r\n<p><strong>Parity:<\/strong> Must be None<\/p>\r\n<p>&nbsp;<\/p>\r\n<p>&nbsp;<\/p>\r\n<p><strong>QS6000 and QSL Scanner Parts;<\/strong><\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-29072 size-full\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-14.jpg\" alt=\"\" width=\"795\" height=\"716\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-14.jpg 795w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-14-300x270.jpg 300w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-14-768x692.jpg 768w\" sizes=\"auto, (max-width: 795px) 100vw, 795px\" \/><\/p>\r\n<p><strong>COM Port:<\/strong> You need to select your COM Ports accordingly<\/p>\r\n<p><strong>Baud Rate:<\/strong> Must be 9600<\/p>\r\n<p><strong>Data Bits:<\/strong> Must be 8<\/p>\r\n<p><strong>Stop Bits:<\/strong> Must be One<\/p>\r\n<p><strong>Parity:<\/strong> Must be None<\/p>\r\n<p>&nbsp;<\/p>\r\n<p>&nbsp;<\/p>\r\n<p><strong>RS232Imager and RS232Scanner Parts;<\/strong><\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-29076 size-full\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-15-1.jpg\" alt=\"\" width=\"795\" height=\"716\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-15-1.jpg 795w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-15-1-300x270.jpg 300w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-15-1-768x692.jpg 768w\" sizes=\"auto, (max-width: 795px) 100vw, 795px\" \/><\/p>\r\n<p><strong>COM Port:<\/strong> You need to select your COM Ports accordingly<\/p>\r\n<p><strong>Baud Rate:<\/strong> Must be 9600<\/p>\r\n<p><strong>Data Bits:<\/strong> Must be 8<\/p>\r\n<p><strong>Stop Bits:<\/strong> Must be One<\/p>\r\n<p><strong>Parity:<\/strong> Must be None<\/p>\r\n<p>After completing necessary editings, click on <strong>Apply<\/strong> button.<\/p>\r\n<p>&nbsp;<\/p>\r\n<h4><strong>4.2.3. Scales Section<\/strong><\/h4>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-29078 size-full\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-17.jpg\" alt=\"\" width=\"795\" height=\"859\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-17.jpg 795w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-17-278x300.jpg 278w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2023\/11\/Datalogic-Magellan-Scale-17-768x830.jpg 768w\" sizes=\"auto, (max-width: 795px) 100vw, 795px\" \/><\/p>\r\n<p><strong>COM Port:<\/strong> You need to select your COM Ports accordingly<\/p>\r\n<p><strong>Baud Rate:<\/strong> Must be 9600<\/p>\r\n<p><strong>Data Bits:<\/strong> Must be 8<\/p>\r\n<p><strong>Stop Bits:<\/strong> Must be One<\/p>\r\n<p><strong>Parity:<\/strong> Must be None<\/p>\r\n<p><strong>RTS Control:<\/strong> Enabled<\/p>\r\n<p><strong>Units:<\/strong> Metric<\/p>\r\n<p>&nbsp;<\/p>\r\n","protected":false},"excerpt":{"rendered":"<p>In this document, it will be explained how to configure Datalogic Magellan Scale on SambaPOS. &nbsp; How It Works; https:\/\/www.youtube.com\/watch?v=Oqiux8mtXjI &nbsp; &nbsp; Important Note: In order to use Datalogic Magellan Scale Integration you need to have minimum SambaPOS 5.7.12 version. &nbsp; 1.\u00a0Installing Scale Module on Samba Market You need to install\u00a0Scale Module\u00a0on Samba Market and\u00a0restart [&hellip;]<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[11],"tags":[],"class_list":["post-29030","post","type-post","status-publish","format-standard","hentry","category-additional-modules"],"_links":{"self":[{"href":"https:\/\/kb.sambapos.com\/en\/wp-json\/wp\/v2\/posts\/29030","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/kb.sambapos.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/kb.sambapos.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/kb.sambapos.com\/en\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/kb.sambapos.com\/en\/wp-json\/wp\/v2\/comments?post=29030"}],"version-history":[{"count":25,"href":"https:\/\/kb.sambapos.com\/en\/wp-json\/wp\/v2\/posts\/29030\/revisions"}],"predecessor-version":[{"id":48900,"href":"https:\/\/kb.sambapos.com\/en\/wp-json\/wp\/v2\/posts\/29030\/revisions\/48900"}],"wp:attachment":[{"href":"https:\/\/kb.sambapos.com\/en\/wp-json\/wp\/v2\/media?parent=29030"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/kb.sambapos.com\/en\/wp-json\/wp\/v2\/categories?post=29030"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/kb.sambapos.com\/en\/wp-json\/wp\/v2\/tags?post=29030"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}