{"id":26029,"date":"2022-01-14T08:56:26","date_gmt":"2022-01-14T08:56:26","guid":{"rendered":"https:\/\/kb.sambapos.com\/?p=26029"},"modified":"2022-01-14T08:56:26","modified_gmt":"2022-01-14T08:56:26","slug":"8-8-avery-berkel-scale-setup","status":"publish","type":"post","link":"https:\/\/kb.sambapos.com\/en\/8-8-avery-berkel-scale-setup\/","title":{"rendered":"8.8. Avery Berkel Scale Setup"},"content":{"rendered":"\n<p>In this document, it will be explained how to setup Avery Berkel brand scale with SambaPOS.<\/p>\n<p>\u00a0<\/p>\n<h3>1. Installing Scale Module on Samba Market<\/h3>\n<p>You need to install <strong>Scale Module<\/strong> on Samba Market and restart the SambaPOS.<\/p>\n<p>Main Menu &gt; Samba Market &gt; Click on Install button in Scale Module Part.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-26030 size-large\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-01-1024x576.jpg\" alt=\"\" width=\"640\" height=\"360\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-01-1024x576.jpg 1024w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-01-300x169.jpg 300w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-01-768x432.jpg 768w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-01-1536x864.jpg 1536w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-01.jpg 1920w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><\/p>\n<p>After installing the scale module, you need to restart SambaPOS.<\/p>\n<p>\u00a0<\/p>\n<p>\u00a0<\/p>\n<h3>2. Adding Custom Scale as a Device from SambaPOS<\/h3>\n<p>Go to<strong> Main Menu &gt; Manage &gt; Settings &gt; Local Settings &gt; Devices &gt; Add Device &gt; Select Custom Scale &gt;<\/strong> Click on <strong>Settings<\/strong> button and configure it according to below image.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-26036 size-large\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-02-1-1024x576.jpg\" alt=\"\" width=\"640\" height=\"360\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-02-1-1024x576.jpg 1024w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-02-1-300x169.jpg 300w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-02-1-768x432.jpg 768w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-02-1-1536x864.jpg 1536w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-02-1.jpg 1920w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><\/p>\n<p><strong>Match Pattern:<\/strong> <code>(?:[0-9]+\\.[0-9]+)<\/code><\/p>\n<p><strong>Port:\u00a0<\/strong>Select the port your device is connected.<\/p>\n<p>\u00a0<\/p>\n<p>\u00a0<\/p>\n<h3>3. Adding Avery Automation Command<\/h3>\n<p><strong>Main Menu &gt; Manage &gt; Automations &gt; Automation Commands &gt;<\/strong> Here, click on <strong>Add Automation Command<\/strong> button.<\/p>\n<p><strong>General Settings Section;<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-26038 size-large\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-03-1024x576.jpg\" alt=\"\" width=\"640\" height=\"360\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-03-1024x576.jpg 1024w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-03-300x169.jpg 300w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-03-768x432.jpg 768w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-03-1536x864.jpg 1536w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-03.jpg 1920w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><\/p>\n<p><strong>Name:<\/strong> Avery<\/p>\n<p><strong>Button Header:<\/strong> Avery<\/p>\n<p>\u00a0<\/p>\n<p><strong>Mappings Section;<\/strong><\/p>\n<p>Add a line by clicking on <strong>Add<\/strong> button and set it as shown in the image.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-26040 size-large\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-04-1024x576.jpg\" alt=\"\" width=\"640\" height=\"360\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-04-1024x576.jpg 1024w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-04-300x169.jpg 300w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-04-768x432.jpg 768w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-04-1536x864.jpg 1536w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-04.jpg 1920w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><\/p>\n<p>After completing necessary editings, click on <strong>Save<\/strong> button.<\/p>\n<p>\u00a0<\/p>\n<p>\u00a0<\/p>\n<h3>4. Adding Send Data to Scale Action<\/h3>\n<p><strong>Main Menu &gt; Manage &gt; Automations &gt; Actions &gt;<\/strong> Here, click on <strong>Add Action<\/strong>\u00a0button.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-26044 size-large\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-05-1-1024x549.jpg\" alt=\"\" width=\"640\" height=\"343\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-05-1-1024x549.jpg 1024w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-05-1-300x161.jpg 300w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-05-1-768x412.jpg 768w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-05-1-1536x824.jpg 1536w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-05-1.jpg 1920w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><\/p>\n<p><strong>Action Name:\u00a0<\/strong>Send Data To Scale Device<\/p>\n<p><strong>Action Type:\u00a0<\/strong>Send Data To Scale Device<\/p>\n<p><strong>Parameters:<\/strong><\/p>\n<p><strong>Data:<\/strong> W<\/p>\n<p><strong><span style=\"color: #ff0000;\">Important Note:<\/span><\/strong><\/p>\n<p>This brand and model scale is not a scale that sends continuous weighing data. According to its own standard, it waits for the W command to send the current weighing information. Since it does not send automatic weighing, when we want to receive the weighing, we send W by clicking this button. You may need to send different commands on the scales you will use. You should learn this from the service of your scale brand.<\/p>\n<p><strong>Send CR:<\/strong> True<\/p>\n<p>After completing necessary editings, click on <strong>Save<\/strong> button.<\/p>\n<p>\u00a0<\/p>\n<p>\u00a0<\/p>\n<h3>5. Adding Send Data to Scale Rule<\/h3>\n<p><strong>Main Menu &gt; Manage &gt; Automations &gt; Rules &gt;<\/strong> Here, click on <strong>Add Rule<\/strong>\u00a0button.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-26046 size-large\" src=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-06-1024x549.jpg\" alt=\"\" width=\"640\" height=\"343\" srcset=\"https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-06-1024x549.jpg 1024w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-06-300x161.jpg 300w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-06-768x412.jpg 768w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-06-1536x824.jpg 1536w, https:\/\/kb.sambapos.com\/wp-content\/uploads\/2022\/01\/Avery-06.jpg 1920w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><\/p>\n<p><strong>Rule Name:<\/strong> Send Data To Scale Device<\/p>\n<p><strong>Event Name:<\/strong> Automation Command Executed<\/p>\n<p><strong>Execute Rule if:<\/strong> Matches<\/p>\n<p><strong>Add Custom Constraint:<\/strong><\/p>\n<p>Automation Command Name|Equals|Avery<\/p>\n<p><strong>Select Actions:<\/strong><\/p>\n<p><strong>Action:<\/strong> Send Data to Scale Device<\/p>\n<p>After completing necessary editings, click on <strong>Save<\/strong> button.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>In this document, it will be explained how to setup Avery Berkel brand scale with SambaPOS. \u00a0 1. Installing Scale Module on Samba Market You need to install Scale Module on Samba Market and restart the SambaPOS. Main Menu &gt; Samba Market &gt; Click on Install button in Scale Module Part. After installing the scale [&hellip;]<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[11],"tags":[],"class_list":["post-26029","post","type-post","status-publish","format-standard","hentry","category-additional-modules"],"_links":{"self":[{"href":"https:\/\/kb.sambapos.com\/en\/wp-json\/wp\/v2\/posts\/26029","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/kb.sambapos.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/kb.sambapos.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/kb.sambapos.com\/en\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/kb.sambapos.com\/en\/wp-json\/wp\/v2\/comments?post=26029"}],"version-history":[{"count":3,"href":"https:\/\/kb.sambapos.com\/en\/wp-json\/wp\/v2\/posts\/26029\/revisions"}],"predecessor-version":[{"id":26048,"href":"https:\/\/kb.sambapos.com\/en\/wp-json\/wp\/v2\/posts\/26029\/revisions\/26048"}],"wp:attachment":[{"href":"https:\/\/kb.sambapos.com\/en\/wp-json\/wp\/v2\/media?parent=26029"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/kb.sambapos.com\/en\/wp-json\/wp\/v2\/categories?post=26029"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/kb.sambapos.com\/en\/wp-json\/wp\/v2\/tags?post=26029"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}